Technical Data and Specifications

KHS Innofill filling and sealing machine - DRS VF / PET 120/18 SV 30

Working pressure during filling min. 8 bar
(Working pressure must be at least 2,0 bar above filling pressure)

Usage of working pressured air, no peak usage, per 1000 container 0.32 Nm°
This value is divided as:

Working air pressure (lift cylinder) per 1000 containers 0.12 Nm*
Valve pneumatic per 1000 containers 0.2 Nm*

Ventilation of electronic devices 2 Nm*/h
Control system of valve pneumatic 2.5 Nm*/h

SV-Hopper sterile air consumption 5 Nm*/h
Sterile-working pressure 8 bar
Water supply gauge pressure min. 5 bar
Splinter washout system water consumption - per 30 I process
(No continuous operation)

 

PIPING:
Nominal size of beverage pipeline 1 00 NW
Nominal size of return line 80 NW
Nominal size of air supply 25 NW
Nominal size of water supply cold/hot water 50 NW
Volume ring bowl, total 462 I
Volume ring bowl, beverage 230 I

All information is indicative.
Only the technical data are binding.
 